To select the front sensor or the adjustable sensor, select the sensor to be used from "Setup" on the menu screen -> "Sensor Setup" -> "Sensor Select."
1. Select label detection sensor (see-through sensor). Select "See Through" from "Setup" on the menu screen -> "Sensor Setup" -> "Media Sensor."
2. Peel a label and set the media so that only the backing paper (glassine paper) reaches the platen roller and media sensor. (In the case of media (labels) with black lines, take care to ensure that the black line does not reach the media sensor.) Then, lock the head unit.
3. Adjust the sensors. Select "See Through" from "Test & Info" on the menu screen -> "Test Mode" -> "Auto Calibration," and press the "OK" button at the bottom of the screen. Press the "Start" button on the screen displayed, and the sensor will be automatically adjusted.
4. If the automatic adjustment is completed normally, "OK" will be displayed on the screen. If it is completed abnormally (adjustment not possible), the error LED flashes, and "Failed" will be displayed on the screen.
1. Select the black mark detection sensor (reflective sensor). Select "Reflect" from "Setup" on the menu screen -> "Sensor Setup" -> "Media Sensor."
2. Set the media so that the media covers the platen roller and media sensor. Set that media so that black lines or gaps between labels do not cover the sensor.
・Using continuous media and label media without gaps between labels
Set the media so that a section without a black line (or label face stock for label media) does cover the platen roller and media sensor.
・Using label media with gaps
Peel a label and set the media so that only the backing paper (glassine paper) reaches the platen roller and media sensor.
3. Adjust the sensors. Select "Reflect" from "Test & Info" on the menu screen -> "Test Mode" -> "Auto Calibration," and press the "OK" button at the bottom of the screen. Press the "Start" button on the screen displayed, and the sensor will be automatically adjusted.
4. If the automatic adjustment is completed normally, "OK" will be displayed on the screen. If it is completed abnormally (adjustment not possible), the error LED flashes, and "Failed" will be displayed on the screen.
1. Select the continuous media detection sensor (reflective sensor). Select "None" from "Setup" on the menu screen -> "Sensor Setup" -> "Media Sensor."
2. Set the media so that the media covers the platen roller and media sensor. If the media has black lines, do not set the media so that a black line is between the sensors.
3. Adjust the sensors. Select "Reflect" from "Test & Info" on the menu screen -> "Test Mode" -> "Auto Calibration," and press the "OK" button at the bottom of the screen. Press the "Start" button on the screen displayed, and the sensor will be automatically adjusted.
4. If the automatic adjustment is completed normally, "OK" will be displayed on the screen. If it is completed abnormally (adjustment not possible), the error LED flashes, and "Failed" will be displayed on the screen.